SVL(C9500-32C SVL) -------- Standalone switch (C9500-32C) Port-channel is configured between 2 devices. Port-channel in down state after reload of switch due to issue with EEM script.
Reload along with EEM script. There is an EEM script which is used on the standalone switch. This EEM script [post reload of standalone switch], shuts the port-channel and after a delay of 5 minutes should un-shut the port-channel: event manager applet shutdown-loopback-after-restart event syslog occurs 1 pattern "%SYS-5-RESTART: System restarted" action 1.0 cli command "enable" action 2.0 cli command "configure terminal" action 3.0 cli command "interface loopback0" action 3.1 cli command "shutdown" action 4.0 cli command "int po1" action 4.1 cli command "shutdown" action 5.0 cli command "end" action 6.0 syslog msg "Temporary shutdown loopback0 and Po1" event manager applet restore-loopback-after-restart event syslog occurs 1 pattern "%LINK-5-CHANGED: Interface Loopback0, changed state to administratively down" trigger delay 300 action 1.0 cli command "enable" action 2.0 cli command "configure terminal" action 3.0 cli command "interface loopback0" action 5.1 cli command "no shutdown" action 5.2 cli command "int po1" action 5.3 cli command "no shutdown" action 5.5 cli command "end" action 5.7 cli command "wr" action 6.0 syslog msg "Re-Enabling Loopback0 and LISP" Post reload and the completion of the EEM script, the port-channel is not coming up. Issue is not observed if EEM script is not used. After the issue is hit, port-channel can be recovered by just shut/un-shut of the port-channel.
Modify the EEM script to add the physical interface: event manager applet shutdown-loopback-after-restart event syslog occurs 1 pattern "%SYS-5-RESTART: System restarted" action 1.0 cli command "enable" action 2.0 cli command "configure terminal" action 3.0 cli command "interface loopback0" action 3.1 cli command "shutdown" action 4.0 cli command "int po1" action 4.1 cli command "shutdown" action 4.2 cli command "int Hu1/0/1" action 4.3 cli command "shutdown" action 4.4 cli command "int Hu1/0/3" action 4.5 cli command "shutdown" action 5.0 cli command "end" action 6.0 syslog msg "Temporary shutdown loopback0 and Po1" event manager applet restore-loopback-after-restart event syslog occurs 1 pattern "%LINK-5-CHANGED: Interface Loopback0, changed state to administrat ively down" trigger delay 300 action 1.0 cli command "enable" action 2.0 cli command "configure terminal" action 3.0 cli command "interface loopback0" action 3.1 cli command "no shutdown" action 4.0 cli command "int Po1" action 4.1 cli command "no shutdown" action 4.2 cli command "int Hu1/0/1" action 4.3 cli command "no shutdown" action 4.4 cli command "int Hu1/0/3" action 4.5 cli command "no shutdown" action 5.0 cli command "end" action 5.1 cli command "wr" action 6.0 syslog msg "Re-Enabling Loopback0 and LISP" After this change, upon reload of standalone switch, the port-channel comes up automatically after reload [delay of 5 minutes] - no manual intervention needed.
Issue first reported on 16.12.2t. However, issue noticed on new release 17.03.03 as well.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.