Catalyst 3850 we use the objects ifMauDefaultTyp, ifMauAutoNegAdminStatus and ifMauAutoNegCapAdvertisedBits to set the speed and the duplex mode. till 16.9.6, we could see desired value (6C 00, 6C 01) for ifMauAutoNegCapAdvertisedBits fir Gig interface and we can set auto and 10,100 speed for interface. In 16.12.4, we are seeing wrong value as 80 for all interface. While setting, it throws error: Desktop renjithg$ snmpset -v2c -c cisco 10.122.189.150 .1.3.6.1.2.1.26.5.1.1.10.8.1 x 6C01 Error in packet. Reason: wrongValue (The set value is illegal or unsupported in some way) Failed object: SNMPv2-SMI::mib-2.26.5.1.1.10.8.1 Need to fix the issue as NMS rely on this to dynamically control port speed on access switch 3850.