LACP port-channels that contain port-channel members spread across multiple switches can may encounter an issue where post-failover, not all port-channel members will come up properly and result in some interfaces getting suspended. Issue is that post-failover, the LACP Actor ID (the local system ID, not the remote) is different across the switches, causing the interfaces to fail to bundle for LACP. To validate that you are encountering the issue you can use the following commands: 1. show etherchannel summary 2. show lacp counters 3. show lacp internal detail 4. show lacp neighbors detail Below is output that demonstrates the issue: Interface Gi1/1/0/47 is suspended Switch#show etherchannel summary Flags: D - down P - bundled in port-channel I - stand-alone s - suspended H - Hot-standby (LACP only) R - Layer3 S - Layer2 U - in use f - failed to allocate aggregator M - not in use, minimum links not met u - unsuitable for bundling w - waiting to be aggregated d - default port A - formed by Auto LAG Number of channel-groups in use: 1 Number of aggregators: 1 Group Port-channel Protocol Ports ------+-------------+-----------+----------------------------------------------- 10 Po10(SU) LACP Gi1/1/0/47(s) Gi2/1/0/47(P) Output from "show lacp 10 counters" confirms that the issue is not because LACPDUs are not being received. Switch#show lacp 10 counters LACPDUs Marker Marker Response LACPDUs Port Sent Recv Sent Recv Sent Recv Pkts Err ----------------------------------------------------------------------- Channel group: 11 Gi1/1/0/47 214 200 0 0 0 0 0 Gi2/1/0/47 228 211 0 0 0 0 0 Next, the output from "show lacp 10 internal detail" confirms that the Actor System IDs are different Switch#show lacp 10 internal detail Flags: S - Device is requesting Slow LACPDUs F - Device is requesting Fast LACPDUs A - Device is in Active mode P - Device is in Passive mode Channel group 10 Actor (internal) information: Actor Actor Actor Port System ID Port Number Age Flags Gi1/1/0/47 32768,b4de.31b3.6e04 0x930 7s SA LACP Actor Actor Actor Port Priority Oper Key Port State 32768 0xA 0xD Port State Flags Decode: Activity: Timeout: Aggregation: Synchronization: Active Long Yes Yes Collecting: Distributing: Defaulted: Expired: No No No No Actor Actor Actor Port System ID Port Number Age Flags Gi2/1/0/47 32768,005d.73e5.4234 0x1130 18s SA LACP Actor Actor Actor Port Priority Oper Key Port State 32768 0xA 0x3D Port State Flags Decode: Activity: Timeout: Aggregation: Synchronization: Active Long Yes Yes Collecting: Distributing: Defaulted: Expired: Yes Yes No No Output from "show lacp 10 neighbors detail confirms that the partner ID is fine Switch#show lacp 10 neigh det Flags: S - Device is requesting Slow LACPDUs F - Device is requesting Fast LACPDUs A - Device is in Active mode P - Device is in Passive mode Channel group 10 neighbors Partner's information: Partner Partner Partner Port System ID Port Number Age Flags Gi1/1/0/4 32768,2c31.24fa.e580 0x204 12s FA LACP Partner Partner Partner Port Priority Oper Key Port State 32768 0xA 0x7 Port State Flags Decode: Activity: Timeout: Aggregation: Synchronization: Active Short Short Yes No Collecting: Distributing: Defaulted: Expired: No No No No Partner Partner Partner Port System ID Port Number Age Flags Gi2/1/0/4 32768,2c31.24fa.e580 0x206 14s SA LACP Partner Partner Partner Port Priority Oper Key Port State 32768 0xA 0x3D Port State Flags Decode: Activity: Timeout: Aggregation: Synchronization: Active Long Long Yes Yes Collecting: Distributing: Defaulted: Expired: Yes Yes No No The interface will not automatically recover once both switches are back up.
Issue seen on Catalyst 9400 in SVL running 16.12.4 with a non-zero value for the "stack-mac persistent timer "
Do not configure a non-zero value for "stack-mac persistent timer" command or if this is already configured, a full reload will synchronize the MAC addresses properly
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.