Only PTPv2 and PTPv1 packets using 224.0.1.129 as multicast group (UDP 319/320) are supported for L2 flooding inside SDAccess fabric PTPv1 packets for PTPv1 subdomains can use 224.0.1.130, 224.0.1.131 or 224.0.132 which can't be flooded, despite the TTL value of 1
L2 Flooding enabled on the fabric PTPv1 packets not received on remote edge nodes with a group address from 224.0.1.130 to 224.0.1.132 PTPv1 packets for default domain ( 224.0.1.129 ) and PTPv2 are flooded
Use PTPv1 default domains only Use PTPv2 only as all domains and subdomains use the same group address of 224.0.1.129