After reload or OIR the SFP, some ports will go into err-disable state with gbic-invalid error on GLC-TE port.
1. The issue that applies to this particular CDETS *****ONLY happens on some ports of some C3850-12S or some ports of some C3850-24S**** but ****ONLY with some particular SFP modules, see #2 below.**** 2. The issue that applies to this particular CDETS only happens with some GLC-TE V02 from one vendor (SN begins with "AVC") but ****ONLY in some particular switches/ports. See #1 above for detail.**** 3. Slow insertion during OIR exacerbates the problem. 4. Fast insertions during OIR seems to make the problem go away. 5. This does not imply a problem with the switch or the module, just an unfortunate issue with tolerance stack-up in the circuits inside the module and the switch. 6. Issue does not happen with V01 or V03 of GLC-TE for this vendor, or with any other vendor in any other revision. 7. SW version does not have an impact. Please don't e-mail engineer with questions about whether SW version X.X.X is affected.
For OIR, try a faster insertion. Otherwise no workaround is available and module should be RMA'ed.