When Cat3650 or Cat3850 has PSU status monitored via SNMP by polling cefcFRUPowerStatusTable OID, the expected values are returned. However, if a redundant PSU is OIRed then the entry for this PSU will be missing in subsequent responses when polling cefcFRUPowerStatusTable OID via SNMP.
Cat3650 or Cat3850 switch 16.9.x or 16.12.x release [up until fixed release listed below] OIR for PSU was performed PSU status is being monitored via SNMP by poling cefcFRUPowerStatusTable OID
reload the switch and it will be returning expected values via SNMP again
There is no actual impact on the operation of the switch as "show env" can be used to check PSU status via CLI