Loading...
Loading...
When the EMPLSINTD is fully utilized there is a Cylon mgr crash noticed on either the active or the standby RSP. ASR903#show platform hardware pp active resource-usage summary 0 Cylon HW Resource usage Summary Type Maximum Allocated Freed In Use Available for use ------------------------------------------------------------------------------------- EMPLS3LD 26624 23398 23398 0 26624 EMPLSINTD 8192 110206 102014 8192 0 ASR903#dir stby-bootflash:core Directory of stby-bootflash:/core/ 60418 drwx 4096 Jul 23 2020 04:50:40 +00:00 modules 60422 -rw- 12524166 Jul 23 2020 04:41:23 +00:00 ASR903_cylon_mgr_22726_20200723-044050-UTC.core.gz ASR903#show logging | in cylon %MCP_SYS-0-ASSERTION_FAILED: R1/0: cylon_mgr: Assertion failed: Assertion failed: uea-asic/cylon/manager/./adjmgr/src/cylon_adjmgr_utils.c:63: "0" -Traceback= 1#b69140a35940747d096dfd222d98b621 errmsg:18847000+1A00 binos:18B39000+E5BC binos:18B39000+79F8 cylon_manager:1C1C8000+255058 cylon_manager:1C1C8000+255744 cylon_manager:1C1C8000+21A714 cylon_manager:1C1C8000+28A754 cylon_manager:1C1C8000+4CD850 cylon_manager:1C1C8000+4CDDEC cylon_manager:1C1C8000+500154 nile_server:1E477000+35D04 smc:1C126000+3B54 smc:1C126000+40 ..... -- Also noticed the "DYNAMIC EAID EXHAUSTED" and "DYNAMIC FID EXHAUSTED" messages in the show logging.