IPv6 NS probes generated by SISF will not reach an end-device even though IPv4 ARP probes will. Given this the SISF Database IPv6 entries for the host will eventually get STALE until traffic for/from the host is generated. If security-mode guard is active the device could end up with connectivity issues.
The port where the device is connected is configured as an isolated pvlan host port (switchport mode private-vlan host). The device is a silent host type of device which has a statically assigned IPv6, meaning only gleaning traffic is used to refresh SISF DB entries or it relies on SISF Probes and the time interval of traffic generated by the device is greater then the SISF DB stale timer. Switch where the device is connected is running any version prior to 17.1.1
- Place the host port in normal access mode - Make sure the end-device generates traffic so that the SISF DB entry will never STALE
SISF uses IPv4 ARP and IPv6 NS probes in order to refresh it's device database for hosts where glean traffic or other methods are not enough to ascertain that a given end-device is still active. If the end-device is a silent type of host which only generates traffic in a very large interval then the SISF DB IPv6 entry will enter a STALE state. In order to avoid this SISF uses both IPv4 ARP probes and IPv6 NS probes. IPv4 probes are correctly sent to the end-device and the subsequent response refreshes the SISF DB entry. However for IPv6 NS probe messages these are generated by the CPU but never received by the host. Further inject packet analysis shows that the issue is with the vlan that the CPU uses when it generates the respective packet for the probe. In the IPv4 ARP probe case it correctly uses the primary vlan as the source vlan for the packet, this means that when the L2 lookup is done to deliver the packet to the respective destination MAC address, the lookup is done on the primary vlan MAC table which has the proper MAC entry for the end-device, however for IPv6 NS probes the switch instead generates the package with a source vlan which is the secondary vlan. The lookup is then done on the secondary vlan MAC table, however since the port where the end-device connects is an isolated host port, the MAC entry is marked as blocked as to fulfil the logic of an isolated port, and as such the IPv6 NS probe packet is dropped and never sent to the end-device. On versions 17.1.1 and after, this behaviour has been fixed and IPv6 NS probe packets are correctly generated with the source vlan as the primary vlan, meaning they now reach the end-device correctly.
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.