Upon reload, 3850 switches utilizing MAB authentication for certain supplicants will fail to authorize these devices, causing lack of connectivity until the port is flapped. Issue has been seen with specific HP printers, as these printers are deployed across various ports on the switch stack. When checking the output of "show authentication sessions interface " you will see the following: Switch#sh auth sessions int gigabitEthernet 2/0/47 det No sessions match supplied criteria. Interface is up and MAC is learnt: Switch#sh mac add int g2/0/47 Mac Address Table ------------------------------------------- Vlan Mac Address Type Ports ---- ----------- -------- ----- 111 0017.0884.bfef DYNAMIC Gi2/0/47 Switch#sh int g2/0/47 GigabitEthernet2/0/47 is up, line protocol is up (connected) Hardware is Gigabit Ethernet, address is 00e1.6d38.1c2f (bia 00e1.6d38.1c2f) Description: TRAIN1-BW | Panel:D24 MTU 1500 bytes, BW 100000 Kbit/sec, DLY 100 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive set (10 sec) Full-duplex, 100Mb/s, media type is 10/100/1000BaseTX input flow-control is on, output flow-control is unsupported ARP type: ARPA, ARP Timeout 04:00:00 Last input 00:03:58, output 00:00:00, output hang never Last clearing of "show interface" counters never Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0 Queueing strategy: fifo Output queue: 0/40 (size/max) 5 minute input rate 0 bits/sec, 0 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec 22 packets input, 2824 bytes, 0 no buffer Received 0 broadcasts (0 multicasts) 0 runts, 0 giants, 0 throttles 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored 0 watchdog, 0 multicast, 0 pause input 0 input packets with dribble condition detected 452 packets output, 153604 bytes, 0 underruns 0 output errors, 0 collisions, 2 interface resets 0 unknown protocol drops 0 babbles, 0 late collision, 0 deferred 0 lost carrier, 0 no carrier, 0 pause output 0 output buffer failures, 0 output buffers swapped out
Issue has been reported on 3850 switch stacks running 16.9.5 using MAB authentication for supplicants (HP Printers) after the 3850 switch stack reloads.
Shut/no shut the affected port.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.