Cat9K running 16.12.3a will consistently flap when timers are not matching the neighboring N5K. This only happens when running version 16.12.3a, the same configuration in other versions like 16.9.2 will not see the issue.
When running 16.12.3a
Match the timers on both BGP speakers.
BGP timers should be negotiated to the lowest configured on the BGP speaker based of RFC https://tools.ietf.org/html/rfc4271#section-4.2 Hold Time: This 2-octet unsigned integer indicates the number of seconds the sender proposes for the value of the Hold Timer. Upon receipt of an OPEN message, a BGP speaker MUST calculate the value of the Hold Timer by using the smaller of its configured Hold Time and the Hold Time received in the OPEN message. The Hold Time MUST be either zero or at least three seconds.