-Config Synchronization mismatch between RSP3 modules -Standby RSP3 module forced to reload -Below log may be seen before the reload: %HA_CONFIG_SYNC-3-GENERAL: HSCF Failed to sync private-config to standby RP
-ASR903 chassis with active and standby RSP3 modules inserted. -A 'write memory' command is used via a Kron script policy configured as below: kron occurrence daily at XX:XX recurring ! kron policy-list cli write memory !
The recommended workaround is to configure an EEM script as follows: event manager applet SaveconfigScript event timer cron cron-entry "XX XX * * *" action 0.0 syslog msg "CRON_ENTRY triggered - Saving config..." action 1.0 cli command "enable" action 2.0 cli command "wr"