Install mode is not working due to time sync issue. If in-chassis-active (ICA) is configured with a different timezone other then UTC say PDT, in-chassis-standby(ICS) receives an update notification and it uses ‘date -s’ to configure received date and time in UTC format and does NOT change timezone. Because of this difference in ICA and ICS timezone, when install is executed it fails for iCS because response timestamp from ICS is in UTC format but install on ICA assumes all 4 SUPS are in same timezone and format and just checks only date and time which will be different.
1) check if active has timezone configured Switch#show running-config | inc clock clock timezone PDT 7 0 2) if yes, then remove the same and start the install Switch(config)#no clock timezone Switch#write Building configuration...