They configure the device using device template. They have a VLAN 100 configured under VRF100 and then add DHCP pool config for VLAN. Finally switchport config to put service side interfaces on VLAN100. VLAN100 is statically configured with an IP address. Everything works fine until the device is reloaded. Virtual interface losses IP address configured after a reload. we see that the IP address is still there under "show sdwan run"
When reload of cEdge is performed Issue is seen only in C1121 and same templates are used on c1111 and that works fine without any issue
to remove the feature templates for VLAN and then apply that back. It works after