High CPU seen from excessive replication (Inject) of IGMP GSQ. For every 1 GSQ thee will be N number of outbound copies made by CPU. So if there are 100 ports in the vlan we would see 1 in > 100 out replication of IGMP GSQs
IGMP GSQ arrives at switch that does not have the group programmed in snooping table. This causes switch to flood the packet. Example: > Send in GSQ for 239.193.2.2 (NOT 2.1) F340.26.08-3850-1#sh ip igmp snooping groups Vlan Group Type Version Port List ----------------------------------------------------------------------- 25 239.193.2.1 igmp v2 Gi1/0/1 <-- only 2.1 here F340.26.08-3850-1#sh spanning-tree vlan 25 Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/1 Desg FWD 4 128.1 P2p <-- 2.2 GSQ flood Gi1/0/4 Desg FWD 4 128.4 P2p <-- 2.2 GSQ flood /// CPU pcap /// F340.26.08-3850-1#sh mon capture 2 buffer br | i 239.193.2.2 744 0.022653 10.25.1.8 -> 239.193.2.2 IGMPv2 60 Membership Query, specific for group 239.193.2.2 <-- 1 in 745 0.022675 10.25.1.8 -> 239.193.2.2 IGMPv2 60 Membership Query, specific for group 239.193.2.2 <-- 2 out 746 0.022696 10.25.1.8 -> 239.193.2.2 IGMPv2 60 Membership Query, specific for group 239.193.2.2
> have entry populated on switch so flood is stopped (reducing replication to subset of vlan ports) > Change topology so that GSQ from upstream are not seen on downstream switches that did not have the group - In a topology where querier is on shared segment it might hear a leave come from SwA, and send out a GSQ that would also arrive to SwB. If SwB did not have that group in its table the GSQ will flood.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.