When failing over from Active to Standby or during an upgrade, the port-channels with SPANed Native VLAN will go into error disabled on both sides (stakwise-virtual pair and downstream switches) due to "suspended: LACP currently not enabled on the remote port". The condition does not clear until after the destination span port is restored.
Catalyst 9500 stackwise-virtual running IOS-XE 16.12.2 which has a span session configured with a Native VLAN as the source VLAN and the destination port is on the Active switch and a fail-over is performed. interface Port-channel1 switchport mode trunk switchport nonegotiate logging event trunk-status logging event subif-link-status end Port Mode Encapsulation Status Native vlan Po1 on 802.1q trunking 1 Port Vlans allowed on trunk Po1 1-4093 Session 2 --------- Type : Local Session Source VLANs : Both : 1-4092 Destination Ports : Te1/0/11 Encapsulation : Native Ingress : Disabled
Do no span the Native VLAN.
No further description.