The customer upgraded C3650 from 3.6.2a to 16.9.4, and found the config below disappeared in [show running-config]. snmp-server enable traps trustsec-server radius-server provision-secret snmp-server enable traps trustsec-interface unauthorized sap-fail authc-fail supplicant-fail authz-fail snmp-server enable traps trustsec-sxp conn-srcaddr-err msg-parse-err conn-config-err binding-err conn-up conn-down binding-expn-fail oper-nodeid-change binding-conflict I tested on 16.9.4/16.9.5/16.12.3, found that 1. After upgrade, [snmp-server enable traps trustsec-xxx] can be found in [show startup-config] only. 2. After I run [copy startup-config running-config], [snmp-server enable traps trustsec-xxx] disappeared. It can not be found even in [show startup-config]. 3. Then I run [snmp-server enable traps trustsec-xxx] manually with no error, but it is still not displayed in [show running-config].