- Obvious %FMFP-3-OBJ_DWNLD_TO_DP_FAILED: Switch 1 R0/0: fman_fp_image: WRClient download to DP failed log message - Not so obvious fact that switch does not learn this MAC address in all VLANs which will inherently cause unknown unicast flooding in a VLAN where MAC address is not learn
- same MAC address exists in two L3 interfaces (two VLANs, two routed ports, etc) - "device classifier", "macro auto global processing" or "autoconf enable" configured / those features are in use - AND / OR "access-session template monitor" or "access-session monitor" are configured at global level
disable session monitoring feature on affected interfaces conf t authentication convert-to new-style interface range no access-session monitor end If there is a feature dependency for session monitoring on an affected port, you can attempt to disable session monitoring on the other port(s) where the same MAC exists - so long as there is no other feature dependency. Else, you will need to have a unique MAC for all devices plugged into ports on this switch, which leverage these features, regardless of VLAN / broadcast domain / L3 address space Further, the switch may reject this command on interfaces with CTS configured while running IOS-XE version below 17.07.01
Some features depend on session monitoring - which tracks some host data as it relates to the switch for use by those features. Session monitoring does not allow a MAC address to be learned in two broadcast domains. That is, the same MAC cannot exist on two logical or physical interfaces if session monitoring is running on those interfaces and even if those interfaces are two totally separate layer 2 spaces. Having this scenario can lead to the error message observed; %FMFP-3-OBJ_DWNLD_TO_DP_FAILED: Switch 1 R0/0: fman_fp_image: WRClient download to DP failed log message Features such as Device classifier, AutoConf, Auto Smart Ports enable session monitoring globally for all interfaces. Sample topology where this issue can be seen +-------------------+ Gi1/0/1 | C9300-24T DUT | Gi1/0/3 HOST1 ---------------------+ +--------------------- HOST2 0000.0000.0001 VLAN 80 | | VLAN 81 0000.0000.0001 | | +---------+---------+ | Gi1/0/9 | trunk to monitor flood sample configuration of DUT to exhibit this issue ! hostname C9300-24T_DUT ! ip routing ! vlan 80 ! vlan 81 ! macro auto global processing ! interface GigabitEthernet1/0/1 switchport access vlan 80 switchport mode access no shutdown ! interface GigabitEthernet1/0/3 switchport access vlan 81 switchport mode access no shutdown ! interface GigabitEthernet1/0/9 switchport mode trunk switchport trunk allowed vlan 80-81 no shutdown ! interface Vlan80 ip address 192.168.80.1 255.255.255.0 ! interface Vlan81 ip address 192.168.81.1 255.255.255.0 !
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.