A switchport does not learn any MAC address and does not pass traffic. The syslogs show an error similar to the following: %PM-3-INTERNALERROR: Port Manager Internal Software Error (!pm_vlan_test_portlist(vlan, pd->globalNumber): ../switch/pm/pm_vlan.c: 1935: pm_vlan_add_port) -Traceback= 1#c93b8baef7d3bc61cf9973400fbecb68 :55D44699D000+42C267D :55D44699D000+42AAAC8 :55D44699D000+9C43C20 :55D44699D000+9C43B98 :55D44699D000+9C43C20 :55D44699D000+9C43B98 :55D44699D000+42A50E6 :55D44699D000+9C43C20 :55D44699D000+42A364A :55D44699D000+9C43C20 :55D44699D000+42940D4 :55D44699D000+4BEED5C :55D44699D000+5D2DAF3 :55D44699D000+5D2D60E :55D44699D000+9C43B66 :55D44699D000+5D20B0D The running-config shows the correct vlan assigned to the port, however "show interface ... switchport" refers to vlan 1 instead.
This may occur when a vlan is changed in a service-template, or after removing dot1x configuration from a switchport and assigning a static vlan.
Re-apply the vlan configuration again, even if it is already present in the running-config, e.g.: interface TwoGigabitEthernet2/0/1 switchport access vlan 1080
The following is an example of which configuration change could trigger this defect: interface TwoGigabitEthernet2/0/1 no dot1x max-reauth-req no dot1x timeout tx-period no source template access-session inherit disable autoconf access-session inherit disable interface-template-sticky switchport switchport access vlan 1080