Loading...
Loading...
A Catalyst 9000 series switch running any release may see the following errors --- show log --- *Nov 14 11:45:13.552: %ACL_ERRMSG-3-ERROR: Switch 2 R0/0: fed: Input IPv4 Group ACL implicit_deny:xACSACLx-IP-PERMIT_ALL_TRAFFIC-57f6b0d3: configuration could not be applied on Client MAC 0000.0000.0000. *Nov 14 11:45:17.704: %FMFP-3-OBJ_DWNLD_TO_DP_FAILED: Switch 2 R0/0: fman_fp_image: WRClient 0x180a30bf download to DP failed
Seen on any series of Catalyst 9000 series switch running any release where there is a large number of mac moves across 2 or more interfaces that are also enabled with Dot1x and/or MAB authentication
The global configuration command "access-session mac-move deny" will prevent the moves on the local switch from overwhelming internal resources, but will trigger a different error that the authentication has failed. It is encouraged that users investigate the ultimate source of the mac moves to determine if this config is best for your environment.
These logs are the result of the frequent mac moves between Dot1x or MAB secured ports which during each move create a large number of internal updates that the switch must program into hardware. If the volume of mac moves is high enough, these updates will eventually overrun the switches ability to store updates and these logs will be triggered. Cisco has determined that these errors will be expected if an overwhelming number of mac moves are seen as a result of L2 loops, misconfigs/miscabling of port-channeled interfaces, or anything where hundreds/thousands of moves per second are seen on an interface triggering a re-authentication. This defect is for documentation purposes only to help identify a possible cause for this set of errors.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.