Catalyst 9000 switch [such as Cat9300 or Cat9500] operating either in standalone or SVL mode used in MPLS deployment with mVPN running The following can be see in FED trace [show platform software trace message fed switch active] 2019/09/27 08:45:36.760 {fed_F0-0}{1}: [l3_mcast_mroute] [16691]: UUID: 0, ra: 0, TID: 0 (ERR): Could not add L3M ports for Tunnel10 with routed RI 2019/09/27 08:45:36.760 {fed_F0-0}{1}: [l3_mcast_aal] [16691]: UUID: 0, ra: 0, TID: 0 (ERR): Failed to modify adjacency (0x1) 2019/09/27 08:45:36.760 {fed_F0-0}{1}: [asic_l3m] [16691]: UUID: 0, ra: 0, TID: 0 (ERR): AAL-INFRA:L3M Failed to delete ports for 0x56000170 2019/09/27 08:45:36.760 {fed_F0-0}{1}: [asic_l3m] [16691]: UUID: 0, ra: 0, TID: 0 (ERR): AAL-INFRA:L3M Failed to commit replication entry, al_rc(1) 2019/09/27 08:45:36.760 {fed_F0-0}{1}: [asic_l3m] [16691]: UUID: 0, ra: 0, TID: 0 (ERR): AAL-INFRA:L3M Failed to update replication entry, al_rc(1) 2019/09/27 08:45:36.760 {fed_F0-0}{1}: [fed] [16691]: UUID: 0, ra: 0, TID: 0 (ERR):Traceback: [1#cbcc59ab65d1614da9adabf27c042fec ral:7FE200B66000+6BBA8 ral:7FE200B66000+694C5 aal:7FE200E90000+108A2B aal:7FE200E90000+107B4A fedl3:7FE1FC5CA000+4F8D1 fedl3:7FE1FC5CA000+4F078 fedl3:7FE1FC5CA000+58D18 fedl3:7FE1FC5CA000+561F5 fedl3:7FE1FC5CA000+557E7 fedl3:7FE1FC5CA000+9674F doppler_l3_mcast:7FE1E905F000+69DFF fed_katana:7FE1D6923000+D4B72 fed_katana:7FE1D6923000+D4960 fedipc:7FE1FDED0000+CE79 ngwcutils:7FE1FF94D000+C7F6 ngwcutils:7FE1FF94D000+BAB6 prelib:7FE20291E000+3625 pthread:7FE1D8674000+73F4 c:] 2019/09/27 08:45:36.760 {fed_F0-0}{1}: [fed] [16691]: UUID: 0, ra: 0, TID: 0 (ERR): SDK:
Catalyst 9000 switch [such as Cat9300 or Cat9500] operating either in standalone or SVL mode used in MPLS deployment with mVPN running nature of multicast traffic is bursty which results in frequent transitions between Default MDT and Data MDT mVPN Tunnel frequently changing state from A [Accept] -> AF [Accept and Forward] or from A [Accept] -> F [Forward]
Not present
Programming of oif's fails when mdt route changes from A to F. Multicast retry mechanism cleans the failed mroutes and reapplying it within 5 seconds. So drop will be seen for 4 seconds.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.