Symptom
False parity error log in console:
*Apr 15 12:20:28.319 IST: %PMAN-3-PROCFAIL: R0/0: root: The process btman has failed (rc 255)
*Apr 15 12:20:28.491 IST: %REDUNDANCY-3-SWITCHOVER: RP switchover (PEER_NOT_PRESENT)
*Apr 15 12:20:28.493 IST: %REDUNDANCY-3-SWITCHOVER: RP switchover (PEER_DOWN)
*Apr 15 12:20:28.493 IST: %REDUNDANCY-3-SWITCHOVER: RP switchover (PEER_REDUNDANCY_STATE_CHANGE)
*Apr 15 12:20:28.540 IST: %IOSXE-3-PLATFORM: R0/0: cmand: Clocking device Parity Error occured <<<<
Conditions
SSO RP switchover
**if "platform hardware soft-parity reload" CLI is present, then System will be reloaded.
Workaround
To prevent reload, don't include "platform hardware soft-parity reload" in CLI.
Further Problem Description
None