* CLI console is very slow. * OCE-LOOP messages seen. * Finally, routers crash for "SSM connection manager" Exception to IOS Thread: Frame pointer 0x3745A008, PC = 0x10AB13B8 UNIX-EXT-SIGNAL: Segmentation fault(11), Process = SSM connection managerNov 22 01:06:50: %OCE-3-LOOP: A loop in the OCE chain has been detected at: 24247()[0x3E5FA290] -Traceback= 1#6a613f3e4f17b1dff7ea1f12b1e5c8a9 :10000000+EB37AC :10000000+EB3B5C :10000000+B01478 :10000000+AB32EC :10000000+B01498 :10000000+4C286EC :10000000+B01498 :10000000+AB32EC :10000000+B01498 :10000000+4C286EC :10000000+B01498 :10000000+AB32EC :10000000+B01498 :10000000+4C286EC :10000000+B01498 :10000000+AB32EC Nov 22 01:07:00: %OCE-3-LOOP: A loop in the OCE chain has been detected at: 24146()[0x3FE8F898]
Crash sen during customer migration of one non-area 0 OSPF area to BGP-labeled unicast solution. The cutover included: removing area 0 in regional route reflectors.
None
None