Random interfaces within L2 LACP etherchannels are going to suspended. Running the command 'show int x/x accounting' for the broken interface of the switch in question is showing LACP counters Tx increasing while Rx are not (the neighbor switch does increment both counters). Further tshooting, issue is isolated to the point where the LACP PDUs from the neighbor switch are received on the broken port (using EPC) but moving the capture to CP is showing those pkts not making it to the CPU. ELAM on the broken port with src MAC of the neighbor switch is showing that the pkt is dropped: "Packet DROPPED Packet dropped due to Auth behavior configuration."
Issue is affecting 16.9.(1-2) and seems to be affecting 16.6.x as well. Cat36xx, Cat38xx, C9407R and C9410R (chassis are fully populated).
L3 LACP not having issues as well as PAgP (L2/L3 config) and mode ON hence as a workaround we could migrate to PAgP (L2) or mode ON. Shut/no shut as well as reload/power-cycle seems having NO effect, issue still happening.