Symptom
1. Running "show inventory" on ASA 5515 / 5525 throws the following driver error in the output :
"Driver Error, invalid sensor query"
2. Running "show environment" (or) "show environment driver" on ASA 5515 / 5525 / 5545 / 5555 shows up driver related error logs like the one shown below :
"Unable to find sensor with entity ID 10 and entity instance 132"
Conditions
Symptom related to "show inventory" is seen on ASA 5515 / 5525 Models.
Symptom related to "show environment" (or) "show environment driver" is seen on ASA 5515 / 5525 / 5545 / 5555 Models.
Workaround
No workaround to get around this error. But these errors do NOT bear any functional impact for the ASA.
Further Problem Description
Running the command "show inventory" on ASA 5515/5525 generates a Driver error in the output
sh inv
Name: "Chassis", DESCR: "ASA 5525-X with SW, 8 GE Data, 1 GE Mgmt, AC"
PID: ASA5525 , VID: V06 , SN: FTX2350W09D
Driver Error, invalid sensor query <<<< Error log in the output of "show inventory"
===========================================================
Running the command 'Show environment' on ASA 5515 / 5525 / 5545 / 5555 platform may generate following errors
Driver Error Statistics:
-------------------------
I2C I/O Errors : 0
GPIO Errors : 0
Ioctl Null Ptr Errors : 0
Poll Errors : 0
Invalid Ioctl Errors : 2
PECI Errors : 0
Unknown Errors : 0
Last 5 Errors:
---------------
1.) Unable to find sensor with entity ID 10 and entity instance 132
Time: 19:27:09 UTC Jul 12 2018
2.) Unable to find sensor with entity ID 10 and entity instance 108
Time: 19:27:09 UTC Jul 12 2018
3.) Unable to find sensor with entity ID 10 and entity instance 128
Time: 19:27:40 UTC Jul 12 2018
4.) Unable to find sensor with entity ID 10 and entity instance 132
Time: 19:27:40 UTC Jul 12 2018
5.) Unable to find sensor with entity ID 10 and entity instance 108
Time: 19:27:40 UTC Jul 12 2018