Loading...
Loading...
Links drop a few seconds after installing 5th, 6th, 7th, or 8th LRM module. (exact number to trigger is variable: some network modules will work with 6 LRM SFPs, some only with 5) Links on previously linked connections do not recover except with a FRU OIR.
This problem is only triggered with SFP-10G-LRM module, and only when several of these modules are plugged in. The problem has been observed with as few as 5 LRM modules, but that is not necessarily the limit. No other type of SFP module has this issue.
No workaround exists at this point. New C9300-NM-8X have correct programming. Future IOS release will correct programming in the FRU. Using other SFP modules does not cause a problem.
Incorrect calibration programming of power supply in the C9300-NM-8X causes premature over-current trigger which causes links to drop.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.