Loading...
Loading...
On standalone or stacked 3850 switches, one of the switches may stop providing PoE on certain ports. The POE stops because those ports have MOSFET fault
This issue may be observed in different(3650, 3850, 9300) platform, because it is triggered by the port controller h/w circuit. Currently we observed on 3850 running 3.6.x or 16.3.x.
Upgrade to IOS release with fix (on all stack members) and then Power-cycle the 'faulty' switch, meaning, remove and re-add the power supplies cables - Power-off the switch and disconnect and re-connect stack-cables - Remove the switch from the stack -if switch is standalone, do power cycle means remove power cable and connect again. If POE is not provided after upgrade/power cycle then the ports have sustained a hw failure and switch needs to be RMAd.
There are different reason if PDs are not getting power up. but here PD is not powering up because the MOSFET fault was observed on ports. MOSFET fault is a pure h/w fault. but some time this fault will be solved by power cycling switch means that is not the real MOSFET fault but because of signaling noise in h/w it is observed and if switch is power cycled it will be solved. so to reduce this type of signaling noise in h/w this fix this applicable.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.