Two switches are in Power stack sharing and not strict mode. Each switch has one 715 PS. So initially total Input power will be 1430W.o initially total Input power will be 1430W. Then they powered off one 715 PS and they are expecting none of the PD's should go to power deny. After removing one 715 PS. CAPOEIRA>sh stack-pow bud Power Stack Stack Stack Total Rsvd Alloc Unused Num Num Name Mode Topolgy Pwr(W) Pwr(W) Pwr(W) Pwr(W) SW PS -------------------- ------ ------- ------ ------ ------ ------ --- --- Powerstack-2 SP-PS Ring 715 39 674 2 2 1 Power Stack PS-A PS-B Power Alloc Avail Consumd Pwr SW Name (W) (W) Budgt(W) Power(W) Pwr(W) Sys/PoE(W) -- -------------------- ----- ----- -------- -------- ------ ----------- 1 Powerstack-2 0 0 396 394 2 81 /41 2 Powerstack-2 715 0 280 280 0 88 /0 -- -------------------- ----- ----- -------- -------- ------ ----------- Totals: 674 2 169 /41 Switch 1 has Power budget 396W, Allocated Power as 394W. The minimum system power for this SKU is 280W. So 396 (Power Budget) ? 280(Minimum Power for SKU) = 116W which is POE available Power for switch 1 But switch 1 has 9 PD's, out of which 7 PD's are already consumed 114W. so the remaining 2 PD's goes to Power deny state due to insufficient POE available power.