Loading...
Loading...
ASR920 may experience a crash in the cylon_mgr process when a point-to-point 10GE link is brought down. If console is monitored during this event, messages such as the following may be observed: *Jun 29 13:21:34.612 UTC: %MCP_SYS-0-ASSERTION_FAILED: SIP0: cylon_mgr: Assertion failed: Assertion failed: uea-asic/cylon/manager/./adjmgr/src/cylon_adjmgr_utils.c:63: "0" -Traceback= 1#b919e61cbba6eef36f7ddd2092a05103 errmsg:A2CE000+2230 binos:A34D000+F500 binos:A34D000+945C cylon_manager:BFA7000+295AA4 cylon_manager:BFA7000+29616C cylon_manager:BFA7000+260A98 cylon_manager:BFA7000+3CCDA4 cylon_manager:BFA7000+167A68 cylon_manager:BFA7000+146B38 cylon_manager:BFA7000+1A23C0 cylon_manager:BFA7000+1A2140 binos: *Jun 29 13:21:51.797 UTC: %PMAN-0-PROCFAILCRIT: SIP0: pvp.sh: A critical process cylon_mgr has failed (rc 134) Jun 29 13:21:57.532 R0/0: %PMAN-3-RELOAD_SYSTEM: Reloading: System will be reloaded Jun 29 13:22:03.989 R0/0: %PMAN-5-EXITACTION: Process manager is exiting: critical process fault, ssfpd, rp_0_0, rc=0
This is observed on releases which have the fix for CSCva18878. In an environment where this is observed, ASR920 nodes are connected back-to-back via built-in Ten Gigabit Ethernet interfaces, and MPLS TE is configured on this link. The crash is seen when the interface is shut down. MPLS TE is believed to be a requirement to hit this issue.
Not known at this time.