When a switch in a stack-wise virtual setup is reloaded and goes into recovery mode it will not correctly add '(recovery-mode)' to the switch name. If the switch is up when it goes into recovery mode it will correctly change the name of the switch.
Any condition that would cause the switch to revert to recovery mode during the boot process, such as config sync, or dual active detection. For example if the SVL was down on a switch stack with dual active detection, and the recovery switch was reloaded it will boot back up with the following error message: Stackwise virtual: Fast Hello running and triggered dual-active recovery, setting hostname to Switch(recovery-mode) The system will then incorrectly not change the name of the switch.
There is no work around,. Recovery mode still works as expected only the switch name is not set correctly.