Loading...
Loading...
Physical Sub interfaces >511 is not supported on N93xx/N95xx platforms. Example: switch(config-subif)# inter ethernet 1/1.512 ^ Invalid interface format at '^' marker. switch(config-subif)# switch# sh ver | i image NXOS image file is: bootflash:///nxos.7.0.3.I2.1.bin switch# conf ter Enter configuration commands, one per line. End with CNTL/Z. switch(config)# inter ethernet 1/1. ? Sub-Interface number ( for SI on satellite port)
only on physical interfaces.
please bind the interface in port-channel if subinterface >511 needs to be created. switch(config)# inter port-channel 100 switch(config-if)# no switchport switch(config-if)# switch(config-if)# inter port-channel 100.4093 switch(config-subif)# sh run inter port-channel 100.4093 !Command: show running-config interface port-channel100.4093 !Time: Tue Nov 10 18:26:36 2015 version 7.0(3)I2(1) interface port-channel100.4093 switch(config-subif)#
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.