Adding port to a vlan does not update running-configuration with "switchport access vlan X" command, hence after reload port would go back to VLAN 1 (default).
03.07.00 or 03.07.01 software version catalyst 3k/4k assign port to a vlan via SNMP (snmpset -v2c -c test 10.106.69.151 1.3.6.1.4.1.9.9.68.1.2.2.1.2.6 i 255)
assign port to a VLAN manually through CLI via "switchport access vlan X" command
When assigning VLAN to the access port on the switch using setSNMP (snmpset -v2c -c test 10.106.69.151 1.3.6.1.4.1.9.9.68.1.2.2.1.2.6 i 255) port does not get any configuration in show running-config interface output. BGL.S.05-4500-1#show running-config interface gigabitEthernet 1/5 Building configuration... Current configuration : 36 bytes ! interface GigabitEthernet1/5 end The vlan database is updated. VLAN Name Status Ports ---- -------------------------------- --------- ------------------------------- 255 VLAN0255 active Gi1/5 ++Expected output of running-configuration BGL.S.05-4500-1#show running-config interface gigabitEthernet 1/5 Building configuration... Current configuration : 36 bytes ! interface GigabitEthernet1/5 switchport access vlan 255 end