Symptom
A log message %IOSXE_SPA-6-UPDOWN: Interface TenGigabitEthernet2/0/0, link down due to local fault is seen while 10G interface is configured for admin down
when we do shut or "no shut" on a TenGig interface in ASR1k
link down due to local/remote fault
Conditions
Seen only for 10G interface.
Further Problem Description
This is only a cosmetic issue in which a level 6 informational message is getting printed while shutting down a 10G interface.
Display of "link down due to local/remote fault" message during a "shut" is not expected and is fixed with the current ddts
Display of "link down due to local/remote fault" message during a "no shut" is expected since the 10G SFP Hardware first brings down the link and then comes back up, this is observed with the link interrupts generated by 10G Hardware. Thus, "link down due to local/remote fault" during "no shut" is expected.