The following message and traceback are see when performing SSO on QuadSup router. *Sep 5 16:00:24.915 IST: %DIAG-SW1-5_STBY-6-DIAG_OK: Switch 1 Module 5: Passed Online Diagnostics *Sep 5 16:02:38.819 IST: %TUN-SW1-5_STBY-3-TUN_HA: Tunnel HA: Tunnel creation on standby: mismatching hw if_index -Traceback= 7FC18DCz 7FDBCB4z 4867660z 4C49438z 4862A44z 4862EA8z 52437ECz 523D094z *Sep 5 16:02:44.155 IST: %COMMON_FIB-SW1-5_STBY-3-FIBIDBINCONS2: An internal software error occurred. Tunnel1 linked to wrong idb Tunnel1 *Sep 5 16:02:44.155 IST: %TUN-SW1-5_STBY-3-TUN_HA: Tunnel HA: Tunnel creation on standby: mismatching hw if_index
It is seen during rapid tunnel interface create/delete or during the SSO.
There is no workaround.
This is a limitation of CEF. CEF has a limitation when there is a back-to-back interface deletion/re-creation as rapid interface re-use was never a design goal. Deleting an interface takes a finite amount of time as it involves asynchronous activity and enough time must be left for the delete to complete before the interface is re-used. Also note that this issue does not have any impact on data packet flow.