Known affected version(s) that were inferred because the vendor did not provide any: 8.0.3.00400
After an upgrade from vCenter 7.x to 8.0 Update 3, while modifying database tables to align with the vCenter 8.x database schema, the CNS.VOLUME_INFO table schema in the CNS.VPX_TABLE might be incorrect. Inserting data into the CNS.VOLUME_INFO table fails with the following error in /var/log/vmware/vsan-health/vsanvcmgmtd.log on vCenter: DB Error while inserting volume ***: Column ALLOCATED_SPACE does not exist in Table Definition of table volume_info" or "Cannot process vStorage objectxxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxx on ds:///vmfs/volumes/**** . As a result, creating PODs is blocked in ContainerCreating state and Persistent Volumes fail to attach to the nodes. This issue is resolved in this release.
https://techdocs.broadcom.com/us/en/vmware-cis/vsphere/vsphere/8-0/release-notes/vcenter-server-update-and-patch-release-notes/vsphere-vcenter-server-80u3e-release-notes.html