After upgrading the ntg3 driver to version 4.1.9.0-4vmw, Broadcom NICs with fiber physical connectivity might lose network. The vmkernel logs on the ESXi host will have traces as below2023-04-21T12:45:18.689Z cpu44:2097903)Device: 507: ntg3:driver->ops.scanDevice:0 ms2023-04-21T12:45:45.007Z cpu2:2097340)ntg3:0000:18:00.0:Ntg3UplinkAssociate:1131:Associated with vmnic02023-04-21T12:45:45.007Z cpu46:2097954)Uplink: 12244: Device vmnic0 not yet opened2023-04-21T12:45:45.007Z cpu46:2097954)Device: 395: uplink_drv:driver->ops.attachDevice :0 ms2023-04-21T12:45:45.007Z cpu46:2097954)Device: 400: Found driver uplink_drv for device 0x461943084701d68c2023-04-21T12:45:45.007Z cpu46:2097954)Uplink: 14658: Opening device vmnic02023-04-21T12:45:45.007Z cpu46:2097954)Uplink: 12269: The default queue id for vmnic0 is 0x44000.2023-04-21T12:45:45.007Z cpu46:2097954)VMKAPIMOD: 110: failed to query port alias for Not found:2023-04-21T12:45:45.007Z cpu46:2097954)Uplink: 12282: enabled port 0x82000002 with mac XX:XX:XX:XX:XX:XX2023-04-21T12:45:45.007Z cpu46:2097954)Uplink: 2750: vmnic0, fast switch on uplink(0x82000002) connected to PPS is not supported2023-04-21T12:45:45.007Z cpu2:2097340)ntg3:vmnic0:Ntg3UplinkStateSet:614:Setting uplink state to 0x1d2023-04-21T12:45:45.007Z cpu2:2097340)ntg3:vmnic0:Ntg3UplinkStartIO:672:Ntg3UplinkStartIO
Changes in the ntg3 driver version 4.1.9.0-4vmw might cause link issues for the fiber physical layer and connectivity on some NICs, such as Broadcom 1Gb, fails to come up.
Link down state condition for Broadcom 1 GB cards is observed when patching to VMware image "VMware-VMvisor-Installer-7.0U3l-21424296" with driver VMW_bootbank_ntg3_4.1.9.0-4vmw.
Upon reboot after patch, the host is in a disconnected state if Broadcom 1 GB cards are used for the management network
This issue is fixed in ESXi 7.0 Update 3m release.ESXi 7.0 Update 3m provides ntg3 driver version 4.1.9.0-5vmw. The fix also adds a module parameter, fifoElastic, which you can enable in case of jumbo frame drops in certain Dell switches. To enable the parameter, use the following command: esxcli system module parameters set -p 'fifoElastic=1' -m ntg3
None
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.