When relocating a VM from one storage policy to another you see the error "Total available resources could not be determined for reservation"Within the vcloud-container-debug.log you see this error message: 2019-01-01 05:30:14,828 | WARN | pool-jetty-8012636 | BatchTask | Error executing backend call. | requestId=<REQUEST_UUID>,request=POST https://vcdhostname/cloud/amfsecure,requestTime=1554370204726,remoteAddress=<IP>:52041,userAgent=Mozilla/5.0 (Windows NT 6.1; Win64; x64) AppleWebKit/537.36 (...,accept=*/* method=vAppService.updateVAppVmWithStorageClasscom.vmware.vcloud.common.reservation.ReservationSystemException: Total available resources could not be determined for reservation at com.vmware.vcloud.common.reservation.dao.impl.ReservationDaoImpl.getTotalAvailable(ReservationDaoImpl.java:389) at com.vmware.vcloud.common.reservation.dao.impl.ReservationDaoImpl.getTotalAvailable(ReservationDaoImpl.java:401) at java.lang.Thread.run(Thread.java:748)Caused by: java.util.concurrent.TimeoutException at java.util.concurrent.FutureTask.get(FutureTask.java:205)
This issue occurs when vCloud Director's reservation system encounters a timeout.By default this is set to 10 seconds.
In vCloud Director 9.7 a new configuration parameter called "vcloud.reservation.callback.timeoutInSeconds" has been added which allows this timeout to be increased.In previous versions of vCloud Director it is not possible to change this timeout.Configuration Parameters such as the above can be added to vCloud Director via the Cell-Management-Tool command on the Cells and using the manage-config subcommand to update the application configuration settings.Example:/opt/vmware/vcloud-director/bin/cell-management-tool manage-config -n vcloud.reservation.callback.timeoutInSeconds -v 50For more information on using this subcommand, see Updating Application Configuration Settings .
To workaround this issue without changing the timeout, set the storage limit to Unlimited for the VDC storage policy. Navigate to the OrganizationSelect the affected Org VDCNavigate to Storage PoliciesRight-click the affected Storage Policy and select PropertiesSelect Unlimited
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.