Powering on a restored virtual machine fails.A virtual machine fails to power on after a restore.In the vSphere Client, you see entries similar to: An error was received from the ESX host while powering on VM virtual_machine. Failed to start the virtual machine. Module DevicePowerOn power on failed. An error was received from the ESX host while powering on VM Guest_recovered. Failed to start the virtual machine. Module DevicePowerOn power on failed. Unable to create virtual SCSI device for scsi0:0, '/vmfs/volumes/5136586a-2f549592-adc7-2c768a4f9620/Guest_recovered.vmdk' Failed to attach filter 'hbr_filter' to scsi0:0: Bad parameter (195887111). hbr_filter missing required option: gid. An error was received from the ESX host while powering on VM Guest_recovered. Failed to start the virtual machine. Module DevicePowerOn power on failed. Unable to create virtual SCSI device for scsi0:0, '/vmfs/volumes/4cba568d-f994f502-f56e-e41f1344f9da/Guest_recovered.vmdk' Failed to attach filter 'None' to scsi0:0: Not found (195887107). An unexpected error was received from the ESX host while powering on VM vm-number You see the following errors under the tasks of ESXi hosts -Task Name : Power On virtual machineStatus : hbr_filter missing required option: gid. Failed to start the virtual machine. Module DevicePowerOn power on failed. Unable to create virtual SCSI device for scsi0:0, '/vmfs/volumes/601af123-ff100a9c-1065-0012b545c010/VMware/VMware.vmdk' Failed to attach filter 'hbr_filter' to scsi0:0: Bad parameter (195887111).Error stack:Module DevicePowerOn power on failed.Unable to create virtual SCSI device for scsi0:0, '/vmfs/volumes/601af123-ff100a9c-1065-0012b545c010/VMware/VMware.vmdk'Failed to attach filter 'hbr_filter' to scsi0:0: Bad parameter (195887111). hbr_filter missing required option: gid.
This issue occurs when the virtual machine configuration file (.vmx) is corrupted.
To resolve this issue, create a new virtual machine configuration file and point it to the existing virtual disk (.vmdk) file.To create a new virtual machine configuration file and point it to the existing .vmdk file: Connect to vCenter Server using the vSphere Client as an administratorNote the original virtual machines configuration so you can recreate it exactlyRight-click the affected virtual machine and click Remove from Inventory Note: The virtual machine must be powered down to remove from inventory Right-click the ESX/ESXi host where you want the virtual machine to runClick the New Virtual MachineSelect CustomSince the old machine was removed from inventory, you can name the virtual machine the same as before or name it differentlySelect the desired datastore for the new virtual machineSelect the same virtual machine version as the original virtual machineSelect the same operating system, CPU, memory, networking, and SCSI controller as the original machineSelect Use an existing virtual diskBrowse to and select the .vmdk file from the original virtual machineIn Advanced options, select the configuration as it was on the original virtual machine. If you do not know what this was, leave it as defaultClick Finish to complete the Create New Virtual Machine wizard This procedure recreates the configuration file (.vmx) for the virtual machine and other supporting files.You can now start the virtual machine from the inventory of the vSphere Client.
Hash out the SCSI disks attached to the hbr_filter in the VMX file. These lines can be hashed or removed completely from the VMX file and it will have no impact on the VM operations or future replication operations. vSphere replication will recreate this information when the VM is added back to replication. #scsi0:0.hbr_filter.rdid = "RDID-1b6d1c5e-234e-362e-29c5-6d77134f9bd7"#scsi0:0.hbr_filter.persistent = "hbr-persistent-state-RDID-1b6d1c5e-234e-362e-29c5-6d77134f9bd7.psf"#scsi0:0.filters = "hbr_filter"#scsi0:1.hbr_filter.rdid = "RDID-56c4254e-cdf7-3f7c-b107-437bf665857f"#scsi0:1.hbr_filter.persistent = "hbr-persistent-state-RDID-56c4254e-cdf7-3f7c-b107-437bf665857f.psf"#scsi0:1.filters = "hbr_filter"#scsi0:2.hbr_filter.rdid = "RDID-412840c8-5012-3e1d-84e3-f6e12249afb1"#scsi0:2.hbr_filter.persistent = "hbr-persistent-state-RDID-412840c8-5012-3e1d-84e3-f6e12249afb1.psf"#scsi0:2.filters = "hbr_filter"Reload the VMX file and power ON the VM Reloading a vmx file without removing the virtual machine from inventory (1026043)
リストアした仮想マシンをパワーオンしようとすると次のエラーで失敗する: An error was received from the ESX host while powering on VM Guest_recovered.vMotioning virtual machines fails with Error: Failed to attach filter 'yyy' to scsi尝试打开已还原虚拟机的电源失败,并显示错误:打开虚拟机电源时收到来自 ESX 主机的错误 (An error was received from the ESX host while powering on VM)
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.