When customer submitted Password Reset Request with Action type:Unlock Account, following warning syslog occurred. Level : Warning Source : Flow Designer Message : FlowCompiler: Reference was not found for 1f3f87a4-7724-4282-b7f1-30af01695509.error_message. Renaming or deleting action input/outputs can cause this issue. Checked the Password Reset Request and its flow context, then confirmed the request and flow completed normally, but warning occurred from Subflow "Password Unlock"
The issue is reproducible in OOTB due to OOTB Subflow:Password Unlock. Subflow : Password Unlock https://<instance>.service-now.com/$flow-designer.do#/sub-flow-designer/c7f21fcf73c073005ae12ea3c4f6a723 There remains deleted data [2.1 > Error Message] in "Action#10 Assign Subflow Outputs". But [3 > Error Message] is correct. Workaround 1.Open the Subflow:Password Unlock and Action#10 Assign Subflow Outputs 2.Replace the datapill from [2.1 > Error Message] to [3 > Error Message] 3.Publish the subflow