Known affected versions were inferred from fixed-version data and were not explicitly confirmed by the vendor: 10.2.16-h7, 11.1.12, 11.2.10-h13, 12.1.4-h5
The earliest recollection of this bug is traced back to PAN-OS 10.2.17 - September 25, 2026. This bug is fixed in PAN-OS versions 11.1.13, 12.1.5, 10.2.17, 11.2.11, 11.1.14. Fixed an issue where PA-400 Series firewalls were not properly caching DNS responses for FQDN objects. The firewall was observed to repeatedly send DNS requests for the same FQDN objects every 10-15 seconds, even after receiving valid responses, despite the minimum FQDN refresh interval being set to a much higher value. This resulted in excessive DNS queries originating from the firewall's management interface. For more information: https://docs.paloaltonetworks.com/ngfw/release-notes/12-1/pan-os-12-1-5-known-and-addressed-issues/pan-os-12-1-5-addressed-issues https://docs.paloaltonetworks.com/pan-os/10-2/pan-os-release-notes/pan-os-10-2-17-known-and-addressed-issues/pan-os-10-2-17-addressed-issues https://docs.paloaltonetworks.com/pan-os/11-1/pan-os-release-notes/pan-os-11-1-13-known-and-addressed-issues/pan-os-11-1-13-addressed-issues https://docs.paloaltonetworks.com/pan-os/11-1/pan-os-release-notes/pan-os-11-1-14-known-and-addressed-issues/pan-os-11-1-14-addressed-issues https://docs.paloaltonetworks.com/pan-os/11-2/pan-os-release-notes/pan-os-11-2-11-known-and-addressed-issues/pan-os-11-2-11-addressed-issues