Known affected versions were inferred from fixed-version data and were not explicitly confirmed by the vendor: 10.1.10-h9, 10.2.4-h32
The earliest recollection of this bug is traced back to PAN-OS 10.1.11 - May 06, 2026. This bug is fixed in PAN-OS versions 10.1.11, 10.2.5. ( VM-Series firewalls in Microsoft Azure environments only ) Fixed an issue where the brdagent process stopped responding due to missed heartbeats, which caused the firewall to reboot. This occurred when the brdagent process and DPDK-managed ports became out of sync after the Azure infrastructure triggered a hotplug event. For more information: https://docs.paloaltonetworks.com/pan-os/10-1/pan-os-release-notes/pan-os-10-1-11-known-and-addressed-issues/pan-os-10-1-11-addressed-issues https://docs.paloaltonetworks.com/pan-os/10-2/pan-os-release-notes/pan-os-10-2-5-known-and-addressed-issues/pan-os-10-2-5-addressed-issues