- 6.3Defect ID: PAN-291661
Fixed an issue on Panorama appliances and Log Collectors where, after an upgrade, Elasticsearch intermittently entered into a Red state before automatically recovering.
- 6.3Defect ID: PAN-294770
( Firewalls in active/passive HA configurations ) Fixed an issue on firewalls where, after failover, certain subnets were missing from the Link State Database, which prevented OSPF routes from being immediately learned due to a Type-7 to Type-5 LSA translation conflict in the ABR when the same LSA was advertised by two peers in the NSSA area.
- 6.3Defect ID: PAN-296752
Fixed an issue where the firewall experienced high management CPU usage and repeatedly rebooted when attempting to retrieve SMART data.
- 6.3Defect ID: PAN-297295
After upgrading to an affected release, the firewall restarts continuously because the brdagent process restarts multiple times and exhausts its restart limit, resulting in a segfault error. This issue occurs when a high burst of traffic is sent to the Azure PA-VM (Palo Alto Networks Virtual Machine), and impacts production environments due to the regular reboots. Workaround : Migrate the VM instance to Dv5 instance type. On these instance types, SYN packets are not routed to the synthetic path, avoiding this condition. Suggested direct resizing paths are: D3_v2/DS3_v2 to D8ds_v5 D4_v2/DS4_v2 to D8ds_v5 D5_v2/DS5_v2 to D16ds_v5 Azure VMs with ephemeral storage can only be resized to another type with ephemeral storage.
- 6.3Defect ID: PAN-294436
( PA-410, PA-440, PA-450, and PA-460 firewalls ) After upgrading to 11.1.6-h6, the Eth1/2, Eth1/3, Eth1/8, and HA interfaces (if configured) fail to display counters and statistics in the CLI and SNMP.