Document Subtype: Security Bulletin Document ID: hpesbst03977en_us Last Updated: 2020-01-18 Release Date: 2020-01-17 Document Version: 1 Potential Security Impact: Local: Multiple Vulnerabilities; Remote: Multiple Vulnerabilities Source: Hewlett Packard Enterprise, HPE Product Security Response Team VULNERABILITY SUMMARY HPE has identified HPE Command View Advanced Edition (CVAE) multiple vulnerabilities. A security problem might occur if a malicious user attacks the system by taking advantage of these vulnerabilities. The following CVAE have vulnerabilities: Device Manager (DevMgr) Tiered Storage Manager (TSMgr) Replication Manager (RepMgr) Hitachi Dynamic Link Manager (HDLM) Hitachi Global Link Manager (HGLM) Automation Director (AutoDir) Configuration Manager (CM) Reference URL: https://www.oracle.com/technetwork/security-advisory/cpujul2019-5072835.html#AppendixJAVA Software Version DevMgr Earlier than 8.7.0-00 TSMgr Earlier than 8.7.0-00 RepMgr Earlier than 8.7.0-00 HDLM Earlier than 8.7.0-00 HGLM Earlier than 8.7.0-00 CM Earlier than 10.0.0-00 AutoDir Windows: Earlier than 10.0.0-01 Linux: Earlier than 10.0.0-00 Frequency of problem: LowSeverity of problem: Medium References: PSRT111092 CVE-2019-2745 CVE-2019-2762 CVE-2019-2766 CVE-2019-2769 CVE-2019-2786 CVE-2019-2816 CVE-2019-2842 CVE-2019-7317 SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. HP XP7 CVAE Earlier than 8.7.0-00 HPE XP7 Command View Advanced Edition Suite Earlier than 8.7.0-00 BACKGROUND CVSS Version 3.0 and Version 2.0 Base Metrics Reference V3 Vector V3 Base Score V2 Vector V2 Base Score CVE-2019-2745 CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N 4.0 (AV:L/AC:M/Au:N/C:P/I:N/A:N) 1.9 CVE-2019-2762 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L 5.3 (AV:N/AC:L/Au:N/C:N/I:N/A:P) 5.0 CVE-2019-2766 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N 3.7 (AV:N/AC:H/Au:N/C:P/I:N/A:N) 2.6 CVE-2019-2769 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N 5.3 (AV:N/AC:L/Au:N/C:N/I:N/A:P) 5.0 CVE-2019-2786 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N 3.7 (AV:N/AC:H/Au:N/C:P/I:N/A:N) 2.6 CVE-2019-2816 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N 4.8 (AV:N/AC:M/Au:N/C:P/I:P/A:N) 5.8 CVE-2019-2842 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L 3.7 (AV:N/AC:M/Au:N/C:N/I:N/A:P) 4.3 CVE-2019-7317 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L 3.7 (AV:N/AC:H/Au:N/C:N/I:N/A:P) 2.6 Information on CVSS is documented in HPE Customer Notice: HPSN-2008-002 RESOLUTION HPE has provided the following updates to resolve the vulnerabilities. Upgrade to the fixed version below or later. DevMgr 8.7.0-00(*1)(*2) TSMgr 8.7.0-00 RepMgr 8.7.0-00 HDLM 8.7.0-00(*4) HGLM 8.7.0-00 HPE XP Automation Director 10.0.0-01 (Windows) (*5) 10.0.0-00 (Linux) (*5) HPE XP Configuration Manager 10.0.0-00 (*6) Notes: The vulnerabilities of Device Manager agent that runs on the following operating systems can only be corrected by upgrading the JDK used by the Device Manager agent to Oracle JDK version 8u201 or later. Red Hat Enterprise Linux 6.x SUSE Linux Enterprise Server 11 Oracle Unbreakable Enterprise Kernel 6.x If Host Data Collector is installed in a different server to which installed DevMgr, the Host Data Collector must also be upgraded. NA The vulnerabilities of HDLM that runs on the following operating systems can only be corrected by upgrading the Java used by the Hitachi Command Suite Common Agent to Oracle JDK/JRE version 8u221 or later. Red Hat Enterprise Linux 5.x Red Hat Enterprise Linux 6.x SUSE Linux Enterprise Server 11 Oracle Linux 5.x Oracle Linux 6.x Oracle Unbreakable Enterprise Kernel 5.x Oracle Unbreakable Enterprise Kernel 6.x This product corresponds to the fixed version of AutoDir. This product corresponds to the fixed version of CM. HISTORY Version:1 (rev.1) - 17 January 2020 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive Software Product Category: The Software Product Category is represented in the title by the two characters following HPSB. 3C = 3COM 3P = 3rd Party Software GN = HP General Software HF = HP Hardware and Firmware MU = Multi-Platform Software NS = NonStop Servers OV = OpenVMS PV = ProCurve ST = Storage Software UX = HP-UX System management and security procedures must be reviewed frequently to maintain system integrity. HPE is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. "HPE is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HPE products the important security information contained in this Bulletin. HPE recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HPE does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HPE will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HPE disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement." ©Copyright 2025 Hewlett Packard Enterprise Development LP Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.
None
HPE has provided the following updates to resolve the vulnerabilities. Upgrade to the fixed version below or later. DevMgr 8.7.0-00(*1)(*2) TSMgr 8.7.0-00 RepMgr 8.7.0-00 HDLM 8.7.0-00(*4) HGLM 8.7.0-00 HPE XP Automation Director 10.0.0-01 (Windows) (*5) 10.0.0-00 (Linux) (*5) HPE XP Configuration Manager 10.0.0-00 (*6) Notes: The vulnerabilities of Device Manager agent that runs on the following operating systems can only be corrected by upgrading the JDK used by the Device Manager agent to Oracle JDK version 8u201 or later. Red Hat Enterprise Linux 6.x SUSE Linux Enterprise Server 11 Oracle Unbreakable Enterprise Kernel 6.x If Host Data Collector is installed in a different server to which installed DevMgr, the Host Data Collector must also be upgraded. NA The vulnerabilities of HDLM that runs on the following operating systems can only be corrected by upgrading the Java used by the Hitachi Command Suite Common Agent to Oracle JDK/JRE version 8u221 or later. Red Hat Enterprise Linux 5.x Red Hat Enterprise Linux 6.x SUSE Linux Enterprise Server 11 Oracle Linux 5.x Oracle Linux 6.x Oracle Unbreakable Enterprise Kernel 5.x Oracle Unbreakable Enterprise Kernel 6.x This product corresponds to the fixed version of AutoDir. This product corresponds to the fixed version of CM. HISTORY Version:1 (rev.1) - 17 January 2020 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive Software Product Category: The Software Product Category is represented in the title by the two characters following HPSB. 3C = 3COM 3P = 3rd Party Software GN = HP General Software HF = HP Hardware and Firmware MU = Multi-Platform Software NS = NonStop Servers OV = OpenVMS PV = ProCurve ST = Storage Software UX = HP-UX