Document Subtype: Security Bulletin Document ID: hpesbnw04373en_us Last Updated: 2024-06-19 Release Date: 2022-10-11 Document Version: 2 Potential Security Impact: Remote: Arbitrary Code Execution, Authentication Bypass Source: Hewlett Packard Enterprise, HPE Product Security Response Team VULNERABILITY SUMMARY Title Multiple Vulnerabilities in Aruba EdgeConnect Enterprise Orchestrator Note: Information originally published in hpe_aruba_networking_-_2022-015.txt Note: A CSAF version of this document exists at hpe_aruba_networking_-_2022-015.json Aruba Product Security Advisory =============================== Advisory ID: ARUBA-PSA-2022-015 CVE: CVE-2022-37913, CVE-2022-37914, CVE-2022-37915 Publication Date: 2022-Oct-11 Status: Confirmed Severity: Critical Revision: 1 Overview Aruba has released patches for Aruba EdgeConnect Enterprise Orchestrator that address multiple security vulnerabilities. Affected Products Aruba EdgeConnect Enterprise Orchestrator (on-premises) Aruba EdgeConnect Enterprise Orchestrator-as-a-Service Aruba EdgeConnect Enterprise Orchestrator-SP and Aruba EdgeConnect Enterprise Orchestrator Global Enterprise Tenant Orchestrators Orchestrator 9.1.2.40051 and below Orchestrator 9.0.7.40108 and below Orchestrator 8.10.23.40009 and below Any older branches of Orchestrator not specifically mentioned Versions of Aruba EdgeConnect Enterprise Orchestrator that are end of life are affected by these vulnerabilities unless otherwise indicated. Details Authentication Bypass Leading to System Takeover in Aruba EdgeConnect Enterprise Orchestrator Web-Based Management Interface (CVE-2022-37913, CVE-2022-37914) Vulnerabilities in the web-based management interface of Aruba EdgeConnect Enterprise Orchestrator could allow an unauthenticated remote attacker to bypass authentication. Successful exploitation of these vulnerabilities could allow an attacker to gain administrative privileges leading to complete compromise of the Aruba EdgeConnect Enterprise Orchestrator host. Internal References: ATLSP-12, ATLSP-25 Severity: Critical CVSSv3.x Overall Score: 9.8 CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Discovery: These vulnerabilities were discovered and reported by Daniel Jensen (@dozernz) via Aruba's Bug Bounty Program. Unauthenticated Remote Code Execution in Aruba EdgeConnect Enterprise Orchestrator Web-Based Management Interface (CVE-2022-37915) A vulnerability in the web-based management interface of Aruba EdgeConnect Enterprise Orchestrator could allow an unauthenticated remote attacker to run arbitrary commands on the underlying host. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise. Internal References: ATLWL-313 Severity: Critical CVSSv3.x Overall Score: 9.8 CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Discovery: This vulnerability was discovered and reported by Daniel Jensen (@dozernz) via Aruba's Bug Bounty Program Affected: This vulnerability only affected the versions listed Aruba EdgeConnect Enterprise Orchestrator (on-premises) 9.1.x branch only Any 9.1.x Orchestrator instantiated as a new machine with a release prior to 9.1.3.40197 Orchestrators upgraded to 9.1.x were not affected. Resolution: If you have a version of Aruba EdgeConnect Enterprise Orchestrator (on-premises) that you believe is affected from the above criteria, please reach out to TAC for resolution assistance. Exploitation and Public Discussion Aruba is not aware of any public discussion or exploit code that target these specific vulnerabilities as of the release date of the advisory. References: CVE-2022-37913 CVE-2022-37914 CVE-2022-37915 SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. Aruba EdgeConnect Enterprise Orchestration Software See information in summary BACKGROUND HPE calculates CVSS using CVSS Version 3.1. If the score is provided from NIST, we will display Version 2.0, 3.0, or 3.1 as provided from NVD. Reference V3 Vector V3 Base Score V2 Vector V2 Base Score CVE-2022-37913 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 9.8 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2022-37914 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 9.8 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2022-37915 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 9.8 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 Information on CVSS is documented in HPE Customer Notice: HPSN-2008-002 These vulnerabilities were discovered and reported by Daniel Jensen (@dozernz) via Aruba's Bug Bounty Program. RESOLUTION Upgrade Aruba EdgeConnect Enterprise Orchestrator to one of the following versions with the fixes to resolve all issues noted in the details section. Aruba EdgeConnect Enterprise Orchestrator (on-premises) Orchestrator 9.2.0.40405 and above Orchestrator 9.1.3.40197 and above Orchestrator 9.0.7.40110 and above Orchestrator 8.10.23.40015 and above Aruba EdgeConnect Enterprise Orchestrator-as-a-Service TAC will automatically create a support case for Aruba (Silver Peak) hosted Orchestrators to be upgraded. Aruba EdgeConnect Enterprise Orchestrator-SP and Aruba EdgeConnect Enterprise Orchestrator Global Enterprise Tenant Orchestrators Service providers must upgrade all tenants to a patched version listed above Aruba does not evaluate or patch product versions that have reached their End of Support (EoS) milestone. Supported versions as of the publication date of this advisory are: Aruba EdgeConnect Enterprise Orchestrator 9.2.x Aruba EdgeConnect Enterprise Orchestrator 9.1.x Aruba EdgeConnect Enterprise Orchestrator 9.0.x Aruba EdgeConnect Enterprise Orchestrator 8.10.x For more information about Aruba's End of Support policy visit: https://www.arubanetworks.com/support-services/end-of-life/ Workaround To minimize the likelihood of an attacker exploiting these vulnerabilities, Aruba recommends that the CLI and web-based management interfaces be restricted to a dedicated layer 2 segment/VLAN and/or controlled by firewall policies at layer 3 and above. HISTORY Version:1 (rev.1) - 11 October 2022 Initial release Version:2 (rev.2) - 18 June 2024 Updating HPE and CSAF links for webpage conversion Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive System management and security procedures must be reviewed frequently to maintain system integrity. HPE is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. "HPE is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HPE products the important security information contained in this Bulletin. HPE recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HPE does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HPE will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HPE disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement." ©Copyright 2025 Hewlett Packard Enterprise Development LP Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.
None
Upgrade Aruba EdgeConnect Enterprise Orchestrator to one of the following versions with the fixes to resolve all issues noted in the details section. Aruba EdgeConnect Enterprise Orchestrator (on-premises) Orchestrator 9.2.0.40405 and above Orchestrator 9.1.3.40197 and above Orchestrator 9.0.7.40110 and above Orchestrator 8.10.23.40015 and above Aruba EdgeConnect Enterprise Orchestrator-as-a-Service TAC will automatically create a support case for Aruba (Silver Peak) hosted Orchestrators to be upgraded. Aruba EdgeConnect Enterprise Orchestrator-SP and Aruba EdgeConnect Enterprise Orchestrator Global Enterprise Tenant Orchestrators Service providers must upgrade all tenants to a patched version listed above Aruba does not evaluate or patch product versions that have reached their End of Support (EoS) milestone. Supported versions as of the publication date of this advisory are: Aruba EdgeConnect Enterprise Orchestrator 9.2.x Aruba EdgeConnect Enterprise Orchestrator 9.1.x Aruba EdgeConnect Enterprise Orchestrator 9.0.x Aruba EdgeConnect Enterprise Orchestrator 8.10.x For more information about Aruba's End of Support policy visit: https://www.arubanetworks.com/support-services/end-of-life/ Workaround To minimize the likelihood of an attacker exploiting these vulnerabilities, Aruba recommends that the CLI and web-based management interfaces be restricted to a dedicated layer 2 segment/VLAN and/or controlled by firewall policies at layer 3 and above. HISTORY Version:1 (rev.1) - 11 October 2022 Initial release Version:2 (rev.2) - 18 June 2024 Updating HPE and CSAF links for webpage conversion Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.