2
11/07/2017
Updated Resolution with permanent fix, Management UI U2
1
10/06/2016
Original document release
When uploading an iso image to the management UI of an HPE Hyper Converged 380 Cluster Appliance, the appliance will stop responding at 30 percent.
Eventually the web interface abruptly exits the upload with no error message.
If multiple attempts are made to upload the iso image, at 100 percent completion, the appliance will display the message, "Unable to import the OVA file: no space left on device:"
Scope
Any HPE Hyper Converged 380 Cluster Appliance version 1.00.02 (or earlier).
Resolution
U2 of the Management UI corrects this issue:
https://h20392.www2.hpe.com/portal/swdepot/displayProductInfo.do?productNumber=CS200-HC