On HPE Synergy servers, during the installation of Red Hat Enterprise Linux or SUSE Linux Enterprise Server on an iSCSI disk either using the hardware or software offload iSCSI host initiator with the network adapters configured in One-View mode, the iSCSI drive is not detected.This occurs because the iSCSI disk is not able to be detected because the inbox drivers does not support the One-View mode.
Any HPE Synergy Servers running RHEL or SLES and configured with any of the following adapters:HPE Synergy 3820C 10/20Gb Converged Network AdapterHPE Synergy 4820C 10/25Gb Converged Network AdapterHPE Synergy 6310C 25GB 50GB Ethernet Adapter ModuleHPE Synergy 6810C 25/50Gb Ethernet AdapterHPE Synergy 6820C 25/50Gb Converged Network Adapter
Add "ip=ibft" as the boot parameter during installation if /boot partition needs be placed on the iSCSi target.Document VersionRelease DateDetails2July 3, 2025Added additional adapters as affected and updated description.1May 25, 2016Original Document Release.