Document Version Release Date Details 4 August 2, 2022 Took out the download instructions for the firmware and replaced them with direct links. Also added Linux and Windows links for firmware version 5.42, and added Windows and VMware links for 1.50 firmware. Updated "HP" to "HPE" throughout the document. 3 May 19, 2014 Updated the Resolution with the condition that HP Smart Array P230i, P430, P431, P731m, P830i, and P830 Controllers must be running firmware version 1.50 before upgrading to version 1.62 (or later). 2 May 6, 2014 Added the HP Smart Array P230i, P430, P431, P731m, P830i, and P830 Controllers as affected products. 1 April 4, 2014 Original Document Release. IMPORTANT: The HPE Smart Array Controller firmware upgrade provided in the Resolution is recommended to prevent or correct a rare Smart Array Controller false failure from occurring. HPE recommends performing this upgrade at the customer's earliest possible convenience. Neglecting to perform the recommended action and not performing the recommended resolution could result in the potential for a Smart Array Controller false failure to occur. In rare instances, on the HPE ProLiant Gen8 servers listed under Platforms Affected and configured with any HPE Smart Array Controller listed in the Scope section (below), a communication issue may occur between HPE Integrated Lights-Out 4 (iLO 4) and the Smart Array Controller. As a result, the Health LED on the server may blink red and a Critical Controller Error: Failed message may be displayed in the HPE Integrated Lights-Out 4 (iLO 4) web interface or in the HPE Integrated Management Log (IML). This is more likely to occur on idle systems configured with one or a few drives. When this iLO 4 communication error occurs, the controller continues to operate properly and other management tools (HPE SSA, SMH, etc.) do not report an error. The error is only recorded in the IML and displayed in the Storage/Drive Arrays tab in the iLO 4 web interface and in all places iLO 4 displays storage data (web, RIBCL, and SNMP): Figure 1 : iLO 4 Drive Arrays Status Screen
Any HPE ProLiant Gen8 server listed under Platforms Affected configured with any of the following HPE Smart Array Controllers and firmware versions: HPE Smart Array Controllers running firmware earlier than version 5.42 HPE Smart Array P220i Controller HPE Smart Array P222 Controller HPE Smart Array P420i Controller HPE Smart Array P420 Controller HPE Smart Array P421 Controller HPE Smart Array P721m Controller HPE Smart Array P822 Controller HPE Smart Array Controllers running firmware earlier than version 1.62 HPE Smart Array P230i Controller HPE Smart Array P430 Controller HPE Smart Array P431 Controller HPE Smart Array P731m Controller HPE Smart Array P830i Controller HPE Smart Array P830 Controller
To avoid HPE Smart Array Controller failure due to this issue, upgrade the HPE Smart Array Controller to the appropriate firmware version stated below, or newer: HPE Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 Controllers Upgrade HPE Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 Controllers Version 5.42 or later: Linux: Software Details - Supplemental Update / Online ROM Flash Component for Linux - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 VMware: Software Details - Online ROM Flash Component for VMware ESXi - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 Windows: Software Details - Online ROM Flash Component for Windows - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 HPE Smart Array P230i, P430, P431, P731m, P830i, and P830 Controllers Upgrade HPE Smart Array P230i, P430, P431, P731m, P830i, and P830 Controllers firmware version to 1.50 or later: Linux: Software Details - Supplemental Update / Online ROM Flash Component for Linux - Smart Array P230i, P430, P431, P731m, P830i, and P830 VMware: Software Details - Online ROM Flash Component for VMware ESXi - Smart Array P230i, P430, P431, P731m, P830i, and P830 Windows: Software Details - Online ROM Flash Component for Windows - Smart Array P230i, P430, P431, P731m, P830i, and P830 RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL: HPE Email Preference Center NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to the Navigation Tips document. SEARCH TIP: For hints on locating similar documents on HPE.com, refer to the Search Tips document. To search for additional advisories related to HPE Smart Array P-series Controllers, use the following search string: +Advisory +ProLiant -"Software and Drivers" +"Smart Array P" +Controller