An HPE QLogic Fibre Channel Adapter firmware update failure message may be observed when an update is performed in the HPE OneView profile or HPE OneView for VMware vCenter (OV4VC) on any HPE Synergy Gen10 or Gen10 Plus server configured with an HPE QLogic Synergy 5830C 32G Adapter booting with VMware vSphere ESXi 9.0 or ESXi 9.1.The firmware update completes; however, the adapter does not report the updated firmware version until after a reboot, which causes HPE OneView to report the firmware update as failed.The following image shows an example of the failure message:
Any HPE Synergy Gen10 or Gen10 Plus server running VMware vSphere ESXi 9.0 or VMware vSphere ESXi 9.1 and configured with HPE Synergy 5830C 32Gb Fibre Channel Host Bus AdapterHPE Synergy 5830C 32Gb Fibre Channel Host Bus Adapter Operating Systems affected: VMware vSphere ESXi 9.0 and VMware vSphere ESXi 9.1
This issue will be resolved in a future version of HPE OneView. This advisory will be updated when a solution is available.Workaround:As a workaround, reboot the server so that the adapter displays the updated firmware version. This issue has no functional impact.Revision HistoryDocument VersionRelease DateDetails2August 17, 2026ESXi 9.0 was added throughout the document, along with other minor edits.1July 20, 2026Original Document Release.