On an HPE Synergy Gen10, HPE Synergy Gen10 Plus, and HPE Synergy Gen11 compute modules with HPE Synergy 4820C 10/20/25Gb Converged Network Adapter or HPE Synergy 6820C 25/50Gb Converged Network Adapter, after an installation of Red Hat Enterprise Linux 9.5 (or later) or 10.1 (or later) installation via Hardware iSCSI Boot-from-SAN (BFS) with Multipath, the system may fail to boot and display the Dracut prompt.
Any HPE Synergy Gen10, HPE Synergy Gen10+, and HPE Synergy Gen11 compute modules with HPE Synergy 4820C 10/20/25Gb Converged Network Adapter or HPE Synergy 6820C 25/50Gb Converged Network Adapter in a hardware boot-from-san Mulitpath configuration with Red Hat Enterprise Linux 9.5 (or later) or Red Hat Enterprise Linux 10.1 (or later).
If this has already occurred, reboot with one path and boot the system and add the path back after initial boot.As a workaround, perform the installation without Logical Volume Manager (LVM) and boot the system with a standard partition. Without LVM, the system will boot properly after the installation.