The HPE Moonshot Chassis Manager 2.0 (CM2) Web User Interface (UI) or CLI may not show the firmware details for the HPE Moonshot Moonshot-45XGc Switch Module after updating the CM2 firmware on a Moonshot 1500 Chassis that includes installed HPE ProLiant m750 Server Blades:This is an intermittent display issue and does not affect functionality.
HPE Moonshot 1500 Chassis with HPE Moonshot 1500 Chassis Manager 2.0 Chassis Controller Firmware that reports HPE ProLiant m750 Server Blade and HPE Moonshot-45XGc Switch Module firmware.
To view the details on the web UI, perform the steps below:Update with theHPE Moonshot Chassis Manager 2.0version 4.3 (19 Jun 2025) or later. This CM2 firmware version includes the enhancement for increased CM2 Redfish timeout.If the issue is still occurring, perform these steps to reset the hardware modules:Reboot the affected switch to clear the condition.If the issue still occurs after the switch is rebooted, power-cycle the Moonshot Chassis (by briefly removing power to the chassis). This will initialize the communications between the CM2 Chassis Manager and the 45XGc Network Switches.
Operating Systems Affected:Not Applicable