On any HPE ProLiant Gen12 server configured with an HPE SN1700Q 64Gb Dual Port/Single Port Fibre Channel Host Bus Adapter (FC HBA) or an HPE SN1610Q 32G Dual Port/Single Port FC HBA, the adapter does not display on the Network page of the iLO after a firmware update to version 2.11.09 and a server restart.If an iLO reset is performed, the adapter will re-appear on the Network page; however, the "State" and "Health" of the adapter is reported as unknown:Below are examples of the errors found on the iLO page.The adapter is listed in the iLO Network page:After the firmware update, the adapter is not shown in the iLO Network page, and the Redfish Response tab brings attention to the iLO error:The AHS logs state the errors:
This issue occurs on any HPE ProLiant Gen12 server configured with the following HPE Fibre Channel Host Bus Adapters:HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus AdapterHPE SN1610Q 32Gb 2-port Fibre Channel Host Bus AdapterHPE SN1700Q 64Gb 1-port Fibre Channel Host Bus AdapterHPE SN1700Q 64Gb 2-port Fibre Channel Host Bus AdapterHPE Service Pack for ProLiant (SPP)/HPE Smart Update Manager (SUM) versions affected:HPE SPP 2025.11.01HPE SUM 12.4.0 and later
NOTE: The adapter functionality and operating system start up is not affected by this issue.This document will be updated when more information becomes available.
Operating Systems Affected:Not Applicable